mee 6501 air quality

develop a document titled “A Permit by Rule (PBR) Evaluation for a Painting Operation” and will serve as a simulation of our work as a contract environmental engineer to an industrial organization planning a painting operation within the United States.

The Scenario:

You have contracted with an industrial organization to engineer and write a state air Permit by Rule (PBR) evaluation for a painting operation facility. According to the local state laws and U.S. Environmental Protection Agency (EPA) laws, the facility must have an air permit before construction begins. Once the facility is completed, the construction air permit will then become the operational air permit for the facility.

As a result, your client wants the air permit to automatically align the painting operation facility into operational compliance with state and federal air quality laws. Consequently, it is extremely important for you to evaluate the planned painting operation against the PBR requirements in order to meet the air permit criteria, using the state guidance document and considering the equipment and chemicals already planned for the facility operations.

You have tabulated the following information from what you have gleaned from the material SDS documents and equipment technical data sheets plan (depending on your scenario selection, each “unit” represents a single aircraft, rail tank car, or vehicle):

Interior Liner Coating Material

10 gallons coating/unit

2 gallons of solvent/unit

Unit Lining Application

Apply interior liners to two (2) units/day

Work five (5) hours/day and four (4) days/week

Unit Lining Curing

Cure interior liners of two (2) units/day

Work five (5) hours/day and four (4) days/week

Interior Liner Cure

Heater fuel source is natural gas-fired drying oven

Heater generates 2.1 million (MM) Btu/hr at maximum 2,500 hrs/year

Unit Lining Design

Cross-draft air plenum

Unit interior is the spray area

Exhaust Fan

10,000 ft3/min (CFM)

1 exhaust fan

Air Makeup Unit

5760 ft3/min (CFM)

1 air makeup system

Filter Openings

20.0 ft2 each

Two (2) filter openings

Coating WV

VOC content

2.8 lb/gal coating

Coating VM

Coating volume

1.0 gal

Water Content

Per gal/coating

1.0 lb/gal

Water Density

Per gal/water

8.34 lb/gal

Coating VW

Water volume

Calculation

Exempt-solvent Content

Per gal/coating

0.5 lb/gal

Exempt-solvent Density

Per gal/exempt solvent

6.64 lb/gal

Coating Ves

Exempt solvent volume

Calculation

Additionally, your state’s department of environmental quality (DEQ) has provided you the following PBR limits:

Potential to Emit (PTE)

100 tons VOC/year

Face Velocity

100 ft/min

Filter Velocity

250 ft/min

VOC/5-hour period

6.0 lbs/hr

Short-term Emissions

1.0 lbs/hr

Long-term Emissions

1.0 tons/yr

From your first visit with your client, these are your notes and process flow sketch reflecting the intended operational design:

  • The client has designed an interior coating spray painting system that allows the interior of each unit to be coated.
  • The operations will involve a stripped-down unit being brought into the facility’s shop.
  • The shop is a steel building with a finished concrete floor and a paint booth for each unit.
  • The unit will be placed in the spray booth.
  • The booth will be opened at one end of the booth for makeup air.
  • The exhaust air will flow through an exhaust chamber at the other end of the unit.
  • For each unit, once the liner application operations are completed, the forced curing (drying) operations will immediately commence.

Instructions:

  1. Closely read the required reading assignment from the textbook and the unit lesson within the study guide, and consider reading the suggested reading.
  2. Select the PBR evaluation document to be for only one of the following: (a) an aircraft manufacturing exterior coating paint booth, (b) a rail tank car interior lining process, or (c) a vehicle exterior coating paint booth. You will continue with this scenario selection for the remaining six units, to complete the entire document.
  3. Using APA style (title page, abstract page, body with level 1 headings, and a reference page) for a research paper, begin drafting a PBR evaluation document. You will add to this document in every subsequent unit with another prescribed level 1 heading, building out the entire document one section at a time.
  4. Make your Unit II work the first level 1 heading (center, bold) titled “General Considerations for Operation,” and describe the scenario that is presented above, while specifically describing the scenario that you selected (aircraft, tank car, or vehicle). While describing your scenario, you must include the environmental, health, and safety (EHS) implications of the work system while pulling from the textbook as well as any other relevant sources that are presented in the unit lesson in the study guide. In your description of the EHS implications of the system, be sure to discuss the natural and anthropomorphic variables causally related to outdoor air pollution. You are required to describe the scenario in at least 200 words (minimum). You may find it convenient to summarize the tabulated information in your General Considerations section of the permit for future reference throughout the rest of the course, but do not attempt to tabulate the information in the exact order as what is presented here (to avoid a high match in SafeAssign).
  5. Also under the first level 1 heading, present a box and line process flow diagram (PFD) drawing of the selected scenario. See the drawing on page 375 of the textbook as an additional example of a PFD if you need assistance understanding how to draw one; do not draw the same system that is provided on that page. Do not hand-draw this, but use the “insert” and “shapes” features within Microsoft Word to construct the PFD. Simple labeled boxes and lines are adequate for this preliminary work, so it is not necessary to present specific shapes in your PFD for your selected scenario.
  6. In your abstract section (page 2 of the document), write one or two sentences that reflect your work for this unit. We will be adding one sentence per unit to reflect our work as we go, with the final abstract length being about 8 to 10 sentences long.

In following units (Units III through VII), the unit lessons will contain information related to the interior surface coating operation by means of practical mathematical calculation examples. Consequently, it is imperative that you read the unit lessons within the study guide in every unit, use the math calculation examples provided in each unit lesson, and consider the current (as well as previous) material from the textbook and the additional information cited and referenced in the study guide for every unit. This project will serve as a comprehensive demonstration of your applied learning of engineering air quality.

Your completed mini project should be a minimum of one page, not counting the title page, abstract page, and reference page. You are required to use at least one outside source, which may be your textbook. All sources used, including the textbook, must be referenced; paraphrased and quoted material must have accompanying APA citations.